Load Ratings Per Channel75 Watts (3.125 Amps) @ 24 Volts DC regulated
System Total300 Watts (12.5 Amps) @ 24 Volts DC regulated
Ripple / Noise<150 mV
Load ProtectionElectronic circuit breaker per channel, each rated at 75 watts nominal / 100 watts maximum; 4 Amp, 125V internal fuse; all channels shut off in case of total system overload
Sequential StartupOutputs activate sequentially when power supply system is enabled (see PWR ON, PWR OFF/SLAVE control)
Power Requirements4 Amps, 100-240 Volts AC, 50/60 Hz
Connections 1 – 8(16) 4-pin 5mm detachable terminal blocks comprising (2) paralleled Cresnet ports per each of (8) output channels;
24 Volt DC power outputs with Cresnet data pass-thru from NET port
NET(1) 4-pin 5mm detachable terminal block;
Ordinarily connects to the Master Cresnet port of a control system;
Cresnet data ‘Y’ and ‘Z’ terminals pass through to ports 1 – 8;
Applying 24 Volts DC to the ‘24’ and ‘G

’ terminals enables the power supply system when in “SLAVE” mode
AC Line(1) attached input power cable (~1 ft long) with inline IEC320 socket;
Connects to grounded AC power source using 3-prong power cable or pigtail cable, both provided
Controls PWR ON, PWR OFF/SLAVE(1) rocker switch; enables/disables the pow

er supply system if no external DC voltage is applied to the NET port, or selects “SLAVE” mode to allow enabling the power supply system remotely by applying an external 24V DC signal to the NET port
RESET 1 – 8(8) miniature pushbuttons; each resets its respective output channel, or momentarily disables the channel while held
SYSTEM RESET(1) miniature pushbutton; resets all output channels sequentially, or momentarily disables all channels while held
SETUP(1) miniature pushbutton; used for touch-settable ID (TSID)
LED Indicators PWR 1 – 8(green) Indicate 24V DC power present at each channel output
OVRLD 1 – 8(red) Indicate a load in excess of 75 watts on a given channel, channel output disabled
SYSTEM OVRLD(red) Indicates a total load in excess of 300 watts on the power supply system, all channels disabled
PWR(green) Indicates power supply system

is enabled
NET(yellow) Indicates communication with Cresnet system
SETUP(red) Used for touch-settable ID (TSID)
Environmental Temperature41 Degrees to 104 Degrees F (5 Degrees to 40 Degrees C)
Humidity10% to 90% RH (non-condensing)
Enclosure ChassisAluminum, black anodized with polycarbonate label overlay, convection-cooled, vented top and sides
MountingSurface mount using (2) integral mounting flanges, or 3U 19-inch rack-mountable (C2N-RMAK rack kit sold separately)
CAEN Automation EnclosureOccupies 1 module space in a single-width enclosure, or 2 side-by-side module spaces in a double-width enclosure (CAEN-MK mounting kit sold separately)
Dimensions Height5.19 in (13.18 cm)
Width13.25 in (33.66 cm)
Depth3.29 in (8.36 cm)
Weight 5.3 lb (2.4 kg)